Hits: 2839 img
Selecting diffusion pump fluid tends to collapse into a single number: viscosity. What actually sets how deep a pump can evacuate is the saturated vapour pressure of the oil. What decides how long that oil lasts is thermal stability. And the variable underneath both is molecular weight. IOTA grades 702, 704 and 705 form a ladder running from the 10⁻⁶ torr region down to 10⁻¹⁰ torr. This article sets the three side by side, states which pump type and duty each one serves, and explains how to handle published figures that disagree.
A common misunderstanding in procurement is treating the vacuum a pump reaches as if it were a property of the oil.
| Concept | Definition | Belongs to | Role in selection |
|---|---|---|---|
| Achievable vacuum (system vacuum) | Result of pump, fluid, cold trap, backing pump and seals acting together | System metric | Used to accept complete equipment |
| Saturated vapour pressure | Pressure at which the fluid is in equilibrium with its own vapour at a stated temperature | Fluid property | Indicates which band the fluid can carry a system into |
| Extrapolated vapour pressure | Room-temperature value extrapolated from high-temperature data | Fluid property | A frequent datasheet convention; the temperature must be stated |
A practical rule: ask a supplier for the vapour pressure at 25°C, not for the vacuum the fluid “can reach”. The second is a system conclusion; the former is the capability of the fluid.
The figures below come from published product material. Note that published data for 702 gives two figure sets for viscosity and flash point; both are flagged beneath the table, and the technical data sheet for the grade being purchased governs.
| Parameter | IOTA 702 | IOTA 704 | IOTA 705 |
|---|---|---|---|
| Chemistry | Mixed phenylmethyl and dimethyl cyclosiloxane | Tetramethyl tetraphenyl trisiloxane | High-phenyl phenylmethyl siloxane |
| CAS number | not uniformly stated | 3982-82-9 | 3390-61-2 |
| Molecular weight | oligomer mixture | about 484 | about 546 |
| Kinematic viscosity (25°C) | 40±3 cSt (some documents: 45±3 cSt) | 38±3 cSt | 170–175 cSt |
| Specific gravity (25°C) | 1.08 | 1.06–1.07 | 1.090–1.100 |
| Refractive index (25°C) | 1.51–1.53 | 1.5500–1.5600 | 1.5765–1.5785 |
| Saturated vapour pressure (25°C) | 1×10⁻⁶ torr | 2×10⁻⁸ torr | 3×10⁻¹⁰ torr |
| Achievable vacuum, no cold trap | 10⁻⁶ torr band | 10⁻⁷–10⁻⁸ torr | 10⁻⁹–10⁻¹⁰ torr |
| Flash point | two published sets: 195°C and 300°C | no lower than 210°C | no lower than 243°C |
| Pour point | about −40°C | −35°C | no higher than −14 to −18°C |
| Shelf life | 2 years | 3 years | 3 years |
The two figure sets for 702 are more sensibly handled as a documentation-version issue rather than a choice. Lock one set into the technical agreement, accept material against that agreement, and keep both sets on file so that a mismatch with older paperwork does not restart the argument.
The differences between the three grades come down to phenyl count and chain length, and therefore to molecular weight.
| Grade | Molecular weight | Position on vapour pressure | Engineering consequence |
|---|---|---|---|
| 702 | oligomer mixture | higher end of the three | Fast start, high throughput, suited to moving large gas volumes quickly |
| 704 | about 484 | roughly two orders below 702 | Reaches the 10⁻⁷–10⁻⁸ torr band with a workable balance of start-up and depth |
| 705 | about 546 | lower end of the three | Reaches the 10⁻⁹–10⁻¹⁰ torr band, used with a cold trap |
From 704 to 705 the molecular weight rises by just about 62 while vapour pressure falls by close to two orders of magnitude. That non-linearity is what added phenyl groups deliver, and it is why “the weights are close” does not mean “the grades are interchangeable”.
| Target vacuum | Grade | Typical duty | Cold trap |
|---|---|---|---|
| 10⁻⁵–10⁻⁶ torr | IOTA 702 | Tube and lamp evacuation, capacitor impregnation, metallised film systems | generally not required |
| 10⁻⁷–10⁻⁸ torr | IOTA 704 | Vacuum coating, vacuum melting, optical coating, R&D rigs | depends on cleanliness requirements |
| 10⁻⁹–10⁻¹⁰ torr | IOTA 705 | Electron microscopy, mass spectrometry, accelerators, surface analysis | recommended |
Read the table downward: state the vacuum the process needs, then step one row up. If the calculation lands half an order short, stay in the current band rather than stepping up for reassurance, because stepping up costs slower start-up and higher pumping resistance.
| Dimension | What it looks like | What it means for buying and upkeep |
|---|---|---|
| Continuous coverage | 702, 704 and 705 span 10⁻⁶ to 10⁻¹⁰ torr | Grade changes stay with one supplier, lowering the risk of mixed fluid |
| Verifiable parameters | Viscosity, gravity, refractive index and vapour pressure can all be re-measured | Refractive index also gives a quick check for cross-contamination between grades |
| Pack sizes | 1 kg bottles, 1 US gallon drums, 5 kg and 25 kg drums, 200 kg steel drums | Covers the path from sample trial to volume production |
| Transport status | Shipped and stored as non-hazardous goods | Warehouse and freight costs stay manageable |
| Storage conditions | −40 to 50°C, dry, out of sunlight | Compatible with ordinary plant conditions |
| Technical support | Selection guidance, sample testing, application response | Fewer trial cycles |
Viscosity affects start-up and pumping, not vacuum depth. Vapour pressure is the deciding property.
System vacuum is the joint result of pump and fluid. Comparing fluids on that basis assigns pump faults to the fluid.
704 and 705 differ by about 62 in molecular weight yet nearly two orders of magnitude in vapour pressure; swapping them changes vacuum behaviour and start-up time directly.
With a trap fitted, a lower grade reaches a deeper vacuum. Removing the trap and trying to recover the loss by changing fluid tends to cost more than it returns.
Published data for 702 carries two sets of viscosity and flash figures. Fix one set in the technical agreement, accept against it, and treat the other as reference.
Mainly saturated vapour pressure and the vacuum band it supports. 702 sits near 1×10⁻⁶ torr for the 10⁻⁶ torr band, 704 at 2×10⁻⁸ torr for 10⁻⁷–10⁻⁸ torr, and 705 at 3×10⁻¹⁰ torr for 10⁻⁹–10⁻¹⁰ torr, normally with a cold trap.
Because added phenyl groups act non-linearly. Moving from about 484 to about 546 in molecular weight drops vapour pressure by close to two orders of magnitude.
Published material gives both 40±3 and 45±3 cSt, with flash point recorded as either 195°C or 300°C. Purchase against the technical data sheet for the actual lot, and lock one figure set into the technical agreement.
Typical causes are system leakage, a missing cold trap or insufficient backing pump capacity. Fluid vapour pressure is one link in the chain, and changing fluid cannot repair a structural shortfall.
It depends on boiler temperature, the gases being pumped and system cleanliness. Practice is to monitor: watch colour, viscosity drift and vacuum decay, then change when discolouration, thickening or sustained vacuum loss appears.
Not advised. Mixing shifts vapour pressure and temperature behaviour, and refractive index cannot tell you whether the ratio is sensible. Drain and clean pump body and jets when switching grades.
Company note: Iota Silicone Oil (Anhui) Co., Ltd., founded in 2010 and based in Bengbu, Anhui, operates a 9,000 m² site with 12,000 m² of floor area and runs R&D and international sales from Nanjing in long-term collaboration with local universities and research institutes. Its diffusion pump fluid line covers grades 702, 704 and 705, supported by technical data sheets, sample testing and selection advice.
Vacuum Diffusion Pump Oils-Products-IOTA